User Manual: Production and R&D Friendly PD and QC Charger Trigger Device
Model: VS-Lab01
1. Overview
This smart Trigger Device allows you to extract selected high-power DC voltage rails—such as 5V, 9V, 12V, 15V, and 20V—from any compatible USB-PD or Quick Charge (QC) Type-C power bank or wall charger.
2. Key Features
Multi-Voltage Output Trigger with LED Indication: 5V, 9V, 12V, 15V, or 20V DC output rails.
Over voltage Protection with Alert Buzzer. Device easily survive on overvoltage (~60V) and alarm will activate when voltage is greater than 21.5V.
OLED Display (Optional): Real-time live readings for Voltage (V) and Current (A).
Dual Operating Modes: Dedicated Auto-Scan and Manual Selection modes.
Display Power Saver: Dedicated toggle button to turn the screen ON/OFF without interrupting output power.
Status LED Indicators: Clear visual indicators for active operating modes and active high-voltage rails (5V/ 9V/ 12/ 15V/ 20V).
Multi Input and Output Ports: 3 Input and 3 Output Port Option (use 1 port at a time).
DC Auxiliary Power supply feature (9V -18V): With this feature device will not drop Charger voltage and circuit will be protected on any surge voltage.
3. Getting Started
Plaintext
[ AUTO MODE LED ] ── Active during automatic voltage scanning
[ MANUAL MODE LED ] ─ Active during fixed voltage selection
[ 5V LED ] ──────── Illuminates when 5V output rail is active
[ 9V LED ] ──────── Illuminates when 9V output rail is active
[ 12V LED ] ──────── Illuminates when 12V output rail is active
[ 15V LED ] ──────── Illuminates when 15V output rail is active
[ 20V LED ] ──────── Illuminates when 20V output rail is active
[ DISPLAY BUTTON ] ─ Press for 3S to toggle screen ON / OFF
Step 1: Connecting Input Power
Connect a USB Type-C cable from a compatible USB-PD/QC charger or power bank into the module's Type-C Input Port.
Upon plugging in, the OLED display turns ON instantly and shows the default boot status and initial voltage reading.
Step 2: Connecting Your Load
Connect your external project, circuit, or device to the module's Output Screw Terminals / Connectors.
4. Controls & Operating Instructions
A. Display Monitoring & Power Control
Live Readouts: The screen continuously updates real-time output Voltage ($V$) and load Current ($A$).
Display ON/OFF Switch:
Press the Display Push Button for 3S to switch off the screen during extended tests to save energy or prevent glare.
Background Safety: Turning off the display does not cut power to your load. The device continues delivering output power and monitoring internal safety parameters in the background.
Press the button again to turn the screen back ON.
B. Mode Selection & Voltage Control
1. Auto Mode
Indicator: The AUTO MODE LED lights up.
Function: In this mode, the device automatically scans through all supported power profiles (5V $\rightarrow$ 9V $\rightarrow$ 12V $\rightarrow$ 15V $\rightarrow$ 20V) offered by the connected charger.
2. Manual Mode
Indicator: The MANUAL MODE LED lights up.
Function: In this mode, you can manually step through specific voltage levels using the voltage selector buttons.
Status LEDs
- 5V LED: Illuminates when the 5V rail is locked and active.
9V LED: Illuminates when the 9V rail is locked and active.
12V LED: Illuminates when the 12V rail is locked and active.
15V LED: Illuminates when the 15V rail is locked and active.
20V LED: Illuminates when the 20V rail is locked and active.
5. Step-by-Step Voltage Switching Test Procedure
To perform a complete voltage switching test on a USB charger:
Plug the module into the USB-PD charger via the Type-C port.
Press the Mode Selection Button until the Manual Mode LED illuminates.
Use the voltage switch button to step through each output level sequentially: 5V $\rightarrow$ 9V $\rightarrow$ 12V $\rightarrow$ 15V $\rightarrow$ 20V.
Observe the live display readout at each step to confirm the charger steps up its output rail accurately.
If a charger does not support a requested voltage (e.g., a 15V maximum power bank requested for 20V), the device will safely drop back to the highest available lower rail.
6. Safety & Best Practices
Verify Voltage Before Connecting Loads: Always check the selected output voltage on the display or status LEDs before connecting sensitive electronic devices to the output terminals.
Respect Current Limits: Ensure your connected load does not exceed the maximum current rating ($A$) specified by your USB charger.
Avoid Output Short Circuits: Ensure positive and negative output wire leads do not touch while power is active
Contact for Purchase :
VEDYS TECHNOLOGIES PVT. LTD.Address: -
Plot No. 100, First Floor,
Anand Industrial Estate, Mohan Nagar,
Ghaziabad, Uttar Pradesh 201007
IndiaGSTN - 09AAECV9792R1ZZPhone